Ionisers - A401, A403 & A404

The 401 ionizing bar is designed for simplicity and durability incorporating an efficiently basic method of inductive coupling of the high voltage electrode pins.
By non direct coupling the A401 offers shock proof operation for personnel safety and comfort, this does not impact on the bars capacity to neutralize stubborn static charges.
The bar is constructed from an extruded anodized aluminium U section in which the blue ABS electrode segments are flitted. Each electrode segment is fitted with two stainless steel electrode pins, the length of each segment is 20mm.
The bar has two 20mm long isolating blocks, one at each end of the bar, this means that the overall length of bar will have a total of 40mm of non active length regardless of size. The smallest active bar could therefore in theory be only 60mm in length, although we insert on our smallest bar, two electrode segments making the smallest bar we offer 80mm in length, the maximum 4000mm.


A 401
Shockless AC static eliminator bar

 
Technical
Transformer
A301m or A3017
Operating Voltage
7.0 kV+ or - 10%
Pin energy
0.16 milligouels + or - 10%
Max temperature
60 ¡ãC
Length
80 mm-4000mm (operational length always 40mm less than overall length)
H.V. Cable
Standard 2000mm of sliekded H.V. cable-longer lengths available on request.
NB:longer lengths must be specified on order cable can not be retrofitted
Dimensions
See drawing (size in mm)
Weight
500g per metre (exclubing cable)
Consumption
Anodised aluminium frame,containing ABS segments.Stainless steel electrodes pin
Mounting
Standard two M4 x 20 suds-additional studs can be fitled for long bar lengths
Maximum range
25 mm

Model A403 is an extremely powerful, high performance static eliminator bar. The A403 bar has a hot design,whereby the electrode pins are directly connected to the high voltage supply. Whilst this gives a very strong field of ionisation if the electrode pins are touched, the operator will receive a small shock.
The current consumption of A403 is approximately 200ua per metre. This is about 400% higher than the A401shockless bar. The theoretical output of A403 is 400% higher than the A401.
Whilst an operator touching the electrodes whilst connected can receive an unpleasant shock, there is no physical danger as the current output is limited in a maximum of 5 milliamps.



A 403
High performance AC static eliminator bar

Technical Data
Operating voltage
5.5 kV
Consumption
200 micro A/metre
Max temperature
85¡ãC
H.V. cable
2 metres
Weight
600 g/M
Length
95mm to 2000 mm
 

The 404 air assist ionizing bar is designed for simplicity and durability incorporating an efficiently basic method of inductive coupling of the high voltage electrode pins.
By non direct coupling the A404 offers shock proof operation for personnel safety and comfort, this does not impact on the bars capacity to neutralize stubborn static charges.
The bar is constructed from an extruded anodized aluminium reinforced cylindrical section in which the blue ABS electrode segments are flitted. Each electrode segment is fitted with two stainless steel electrode pins, the length of each segment is 20mm. The bar has two isolating blocks at each end of the bar one 25mm the other 42mm, this means that the overall length of bar will have a total of 67mm of non active length regardless of size. The smallest active bar could therefore in theory be only 87mm in length, although we insert on our smallest bar, two electrode segments making the smallest bar we offer 107mm in length, the maximum 1000mm.
The A404 has an additional internal air duct and active face air discharge ports. Fitting compressed air at 2 bar pressure will extend the bars range from 25mm up to 500mm.

A 404
Air assist shockless long range AC static eliminator bar

Technical
Transformer
A301m or A3017
Operating Voltage
7.0 kV+ or - 10%
Pin energy
0.16 milligouels + or - 10%
Max temperature
60¡ãC
Length
80 mm-1000mm (operational length always 40mm less than overall length)
H.V. Cable
Standard 2000mm of shielded H.V. cable-longer lengths available on request.
NB:longer lengths must be specified on order cable can not be retrofitted
Dimensions
See drawing (size in mm)
Weight
750g per metre (exclubing cable)
Consumption
Anodised aluminium frame,containing ABS segments.Stainless steel electrodes pin





¨O CR & Industrical Disposable Products ¨O ESD & Static Control Products¨O CR Equipment & Accessories ¨O Medical Products ¨O Contact us ¨O